Pump Head-Pressure-Specific Gravity

Head and Pressure Conversion

Liquid Head in feet = psi x 2.31
                                         Sp. Gr

Pressure in psi = Head in feet x sp gr
                                        2.31

Liquid Head in feet = psi x 144
                                           W

Pressure in psi = Head in feet x W
                                           W

Where W = Specific weight in pounds per cubic foot of liquid being pumped under pumping conditions:
For Water W = 62.32 lb per cu ft at 68 degrees F.

 

 

 
 

 

 

 

 

 

   
     

 